Журнал микробиологии, эпидемиологии и иммунобиологии (Aug 2019)
EFFECTIVENESS OF THE LOOP-MEDIATED ISOTHERMAL AMPLIFICATION WITH FLUORESCENT DETECTION IN THE DIAGNOSIS OF PARVOVIRUS ENTERITIS IN CARNIVORES
Abstract
The aim of the study was to evaluate the diagnostic value of the method of loop-mediated isothermal amplification of DNA with real-time fluorescent detection (real-time LAMP, or RT-LAMP) on the model of carnivore parvoviruses. Materials and methods. Samples of feces, blood and swabs from the rectum of different species of predatory animals with parvovirus enteritis (n = 39) and healthy animals (n = 31), as well as laboratory strains of mink enteritis virus, were analyzed by RT-LAMP using SYTO-9 and SYTO-82 dyes. Real-time PCR was used as a reference method. Results. In our study, the LAMP method with real-time fluorescence detection (RT-LAMP) in the carnivore parvovirus enteritis model provides high analytical sensitivity (1.5×103 copies of DNA/ml), diagnostic sensitivity and specificity (up to 100% under optimal conditions). Comparison of the two intercalating dyes showed that the SYTO-82 dye provides a higher signal-to-background ratio (22.6 ± 2.1) than the SYTO-9 dye (6.3 ± 1.5) (p <0.0000001 ). At the same time, SYTO-9 dye at the sensitivity limit (10 copies of DNA) provides an increase in fluorescence in the reaction mixture 13 minutes earlier than for SYTO-82 (23 and 36 minutes, respectively). Conclusion. RT-LAMP is a promising method for rapid and highly sensitive «point-of-care» diagnosis of infectious diseases, as well as in conditions of livestock farms or in field conditions.
Keywords