Jornal de Pediatria (Oct 2008)

Razão entre diâmetros torácicos para detecção de hiperinsuflação estática em crianças pela biofotogrametria Chest diameter ratios for detecting static hyperinflation in children using photogrammetry

  • Denise da V. Ricieri,
  • Nelson A. Rosário,
  • Jecilene R. Costa

DOI
https://doi.org/10.1590/S0021-75572008000600006
Journal volume & issue
Vol. 84, no. 5
pp. 410 – 415

Abstract

Read online

OBJETIVOS: Desenvolver um método fotogramétrico capaz de identificar aumento do diâmetro torácico anteroposterior sugestivo de hiperinsuflação pulmonar e testá-lo em crianças asmáticas e não asmáticas. MÉTODOS: Foram conduzidos dois perfis de estudos, sendo um deles a análise descritiva dos diâmetros medidos no nível axilar e xifóideo em imagens fotográficas digitais de 56 crianças, com idade entre 8 e 12 anos, na posição ortostática, e o outro, um estudo caso-controle entre: (a) 19 crianças asmáticas em tratamento há mais de 12 meses; (b) 37 crianças não asmáticas, sem histórico pregresso ou queixas de doenças respiratórias/alérgicas. Os diâmetros foram medidos nas imagens da vista anterior e lateral esquerda pelo uso do programa CorelDraw®, e a esses diâmetros aplicou-se a razão matemática de vista anterior por lateral esquerda para cada nível, gerando o índice denominado razão diametral. A razão diametral próxima ou superior à unidade expressou uma configuração geométrica tendendo ao formato cilíndrico, típico de hiperinsuflação nas imagens radiológicas. RESULTADOS: A análise pelo teste t para amostras independentes mostrou uma média significativamente maior para razão diametral do osso esterno no grupo de crianças asmáticas (p OBJECTIVES: To develop a photogrammetric method capable of identifying increases in anteroposterior chest diameters suggestive of pulmonary hyperinflation, and to test it with both asthmatic and asthma-free children. METHODS: Two distinct study designs were used to achieve these two objectives. The first was a descriptive analysis of diameters measured at the height of the axilla and of the xiphoid on digital images of 56 children aged 8 to 12 years photographed in the orthostatic position. The second was a case-control study of (a) 19 asthmatic children in treatment for at least 12 months; and (b) 37 children free from asthma with no prior history of complaints of respiratory/allergic disease. Diameters were measured on images of the front and left side views using CorelDRAW®, and the ratio between the front and side diameters was calculated for the axillary and xiphoid measurements, providing the diameter ratios. Diameter ratios close to or greater than 1 represent geometry tending towards a cylindrical shape, typical of hyperinflation on radiographs. RESULTS: Analysis with the t test for independent samples revealed a mean diameter ratio at the sternum that was significantly greater in the group of asthmatic children (p < 0.01) than the mean for the whole sample and also than the mean for the children without asthma. CONCLUSIONS: Despite the existence of disagreement on the best instruments, methods and times for identifying hyperinflation, results indicate that a system using diameter ratios obtained by photogrammetry is a promising tool for the identification of a kinesiopathological manifestation that is known to determine air entrapment in asthma patients. Research that combines clinical data with longitudinal intrapatient follow-up will be necessary to establish the strength of the evidence found in this study.

Keywords