Physical Review Accelerators and Beams (Apr 2017)

Performance in the vertical test of the 832 nine-cell 1.3 GHz cavities for the European X-ray Free Electron Laser

  • D. Reschke,
  • V. Gubarev,
  • J. Schaffran,
  • L. Steder,
  • N. Walker,
  • M. Wenskat,
  • L. Monaco

DOI
https://doi.org/10.1103/PhysRevAccelBeams.20.042004
Journal volume & issue
Vol. 20, no. 4
p. 042004

Abstract

Read online Read online

The successful production and associated vertical testing of over 800 superconducting 1.3 GHz accelerating cavities for the European X-ray Free Electron Laser (XFEL) represents the culmination of over 20 years of superconducting radio-frequency R&D. The cavity production took place at two industrial vendors under the shared responsibility of INFN Milano–LASA and DESY. Average vertical testing rates at DESY exceeded 10 cavities per week, peaking at up to 15 cavities per week. The cavities sent for cryomodule assembly at Commissariat à l’énergie atomique (CEA) Saclay achieved an average maximum gradient of approximately 33 MV/m, reducing to ∼30 MV/m when the operational specifications on quality factor (Q) and field emission were included (the so-called usable gradient). Only 16% of the cavities required an additional surface retreatment to recover their low performance (usable gradient less than 20 MV/m). These cavities were predominantly limited by excessive field emission for which a simple high pressure water rinse (HPR) was sufficient. Approximately 16% of the cavities also received an additional HPR, e.g. due to vacuum problems before or during the tests or other reasons, but these were not directly related to gradient performance. The in-depth statistical analyses presented in this report have revealed several features of the series produced cavities.