Известия высших учебных заведений: Проблемы энергетики (Sep 2024)

Optimization of monitoring systems power cable lines

  • R. N. Balobanov,
  • V. M. Bulatova,
  • N. S. Kryuchkov,
  • I. I. Shafikov

DOI
https://doi.org/10.30724/1998-9903-2024-26-4-89-99
Journal volume & issue
Vol. 26, no. 4
pp. 89 – 99

Abstract

Read online

RELEVANCE. The length and complexity of the geography of medium voltage cable lines is at a high level. Such lines extend underground, on supports in the air. In order to constantly maintain the reliability of city power supply at a high level, any interruptions and accidents should be promptly corrected.TARGET. The main goal of the work is to develop the theory of medium voltage CL research, to practically and theoretically substantiate the search for the most convenient and effective installation for CL diagnostics, to study and develop possible modifications of CL diagnostic installations.METHODS. A variant of CL diagnostics based on the CPDA-60 installation is proposed, which makes it possible to find and localize the places where defects occur in the insulation based on the measurement and analysis of partial discharges (PD). Suitable for insulation monitoring in all types of high voltage cables. The CPDA installation can be used when testing new cable lines being put into operation, and to analyze the condition of old cables in operation.RESULTS. Cable lines require an integrated approach to diagnostics and monitoring, since the reliability of modern authentication systems for the generation and distribution of electricity is largely determined by the electrical reliability of electrical equipment. Technical diagnostics of equipment is a key link, the quality of which determines the efficiency of the processes of organizing production activities, strategic planning and renovation of electric grid assets.CONCLUSION. The study and analysis of the presented data and research allows us to form a conclusion regarding the method of measuring and localizing partial discharges (PD) in power cable lines (CL) using the Online Wire Testing System (OWTS) diagnostic system. The OWTS system allows real-time measurements without interrupting cable lines, making it especially valuable to the energy industry. Thanks to the introduction of advanced technologies and signal processing algorithms, the method has high accuracy and sensitivity to minimal manifestations of private discharges, which allows not only to detect, but also to accurately localize the location of defects in the insulation. The use of this method can significantly increase the service life of power cables, reduce the likelihood of sudden accidents and, as a result, reduce the cost of repair and maintenance of electrical power equipment. Ultimately, improvements in diagnostic and monitoring techniques, including the method of measuring and localizing PD in power lines using OWTS, represent a significant step towards improving the reliability and safety of electrical power systems. This will not only reduce operating costs, but also ensure uninterrupted and high-quality power supply to consumers.

Keywords