Biomedicines (Feb 2024)
Exhaled Breath Analysis Detects the Clearance of <i>Staphylococcus aureus</i> from the Airways of Children with Cystic Fibrosis
Abstract
Background: Electronic nose (eNose) technology can be used to characterize volatile organic compound (VOC) mixes in breath. While previous reports have shown that eNose can detect lung infections with pathogens such as Staphylococcus aureus (SA) in people with cystic fibrosis (CF), the clinical utility of eNose for longitudinally monitoring SA infection status is unknown. Methods: In this longitudinal study, a cloud-connected eNose, the SpiroNose, was used for the breath profile analysis of children with CF at two stable visits and compared based on changes in SA infection status between visits. Data analysis involved advanced sensor signal processing, ambient correction, and statistics based on the comparison of breath profiles between baseline and follow-up visits. Results: Seventy-two children with CF, with a mean (IQR) age of 13.8 (9.8–16.4) years, were studied. In those with SA-positive airway cultures at baseline but SA-negative cultures at follow-up (n = 19), significant signal differences were detected between Baseline and Follow-up at three distinct eNose sensors, i.e., S4 (p = 0.047), S6 (p = 0.014), and S7 (p = 0.014). Sensor signal changes with the clearance of SA from airways were unrelated to antibiotic treatment. No changes in sensor signals were seen in patients with unchanged infection status between visits. Conclusions: Our results demonstrate the potential applicability of the eNose as a non-invasive clinical tool to longitudinally monitor pulmonary SA infection status in children with CF.
Keywords