Journal of Clinical Medicine (Apr 2021)

[<sup>18</sup>F]fluoro-ethylcholine-PET Plus 4D-CT (FEC-PET-CT): A Break-Through Tool to Localize the “Negative” Parathyroid Adenoma. One Year Follow Up Results Involving 170 Patients

  • Constantin Smaxwil,
  • Philip Aschoff,
  • Gerald Reischl,
  • Mirjam Busch,
  • Joachim Wagner,
  • Julia Altmeier,
  • Oswald Ploner,
  • Andreas Zielke

DOI
https://doi.org/10.3390/jcm10081648
Journal volume & issue
Vol. 10, no. 8
p. 1648

Abstract

Read online

Background: The diagnostic performance of [18F]fluoro-ethylcholine-PET-CT&4D-CT (FEC-PET&4D-CT) to identify parathyroid adenomas (PA) was analyzed when ultrasound (US) or MIBI-Scan (MS) failed to localize. Postsurgical one year follow-up data are presented. Methods: Patients in whom US and MS delivered either incongruent or entirely negative findings were subjected to FEC-PET&4D-CT and cases from July 2017 to June 2020 were analyzed, retrospectively. Cervical exploration with intraoperative PTH-monitoring (IO-PTH) was performed. Imaging results were correlated to intraoperative findings, and short term and one year postoperative follow-up data. Results: From July 2017 to June 2020 in 171 FEC-PET&4D-CTs 159 (92.9%) PAs were suggested. 147 patients already had surgery, FEC-PET&4D-CT accurately localized in 141; false neg. 4, false pos. 2, global sensitivity 0.97; accuracy 0.96, PPV 0.99. All of the 117 patients that already have completed their 12-month postoperative follow up had normal biochemical parameter, i.e., no signs of persisting disease. However, two cases may have a potential for recurrent disease, for a cure rate of at least 98.3%. Conclusion: FEC-PET&4D-CT shows unprecedented results regarding the accuracy localizing PAs. The one-year-follow-up data demonstrate a high cure rate. We, therefore, suggest FEC-PET-CT as the relevant diagnostic tool for the localization of PAs when US fails to localize PA, especially after previous surgery to the neck.

Keywords