Scientific Reports (Nov 2023)

Application of machine learning standardized integral area algorithm in measuring the scoliosis

  • Shuman Han,
  • Hongyu Zhao,
  • Yi Zhang,
  • Chen Yang,
  • Xiaonan Han,
  • Huizhao Wu,
  • Lei Cao,
  • Baohai Yu,
  • Jin-Xu Wen,
  • Tianhao Wu,
  • Bulang Gao,
  • Wenjuan Wu

DOI
https://doi.org/10.1038/s41598-023-44252-x
Journal volume & issue
Vol. 13, no. 1
pp. 1 – 10

Abstract

Read online

Abstract This study was to develop a computer vision evaluation method to automatically measure the degree of scoliosis based on the machine learning algorithm. For the X-ray images of 204 patients with idiopathic scoliosis who underwent full-spine radiography, histogram equalization of original image was performed before a flipping method was used to magnify asymmetric elements, search for the global maximum pixel value in each line, and scan local maximal pixel value, with the intersection set of two point sets being regarded as candidate anchor points. All fine anchors were fitted with cubic spline algorithm to obtain the approximate curve of the spine, and the degree of scoliosis was measured by the standardized integral area. All measured data were analyzed. In manual measurement, the Cobb angle was 11.70–25.00 (20.15 ± 3.60), 25.20–44.70 (33.89 ± 5.41), and 45.10–49.40 (46.98 ± 1.25) in the mild, moderate and severe scoliosis group, respectively, whereas the value for the standardized integral area algorithm was 0.072–0.298 (0.185 ± 0.040), 0.100–0.399 (0.245 ± 0.050), and 0.246–0.901 (0.349 ± 0.181) in the mild, moderate and severe scoliosis group, respectively. Correlation analysis between the manual measurement of the Cobb angle and the evaluation of the standardized integral area algorithm demonstrated the Spearman correlation coefficient r = 0.643 (P < 0.001). There was a positive correlation between the manual measurement of the Cobb angle and the measurement of the standardized integral area value. Two methods had good consistency in evaluating the degree of scoliosis. ROC curve analysis of the standardized integral area algorithm to measure the degree of scoliosis showed he cutoff value of the standardized integral area algorithm was 0.20 for the moderate scoliosis with an AUC of 0.865, sensitivity 0.907, specificity 0.635, accuracy 0.779, positive prediction value 0.737 and negative prediction value 0.859, and the cutoff value of the standardized integral area algorithm was 0.40 for the severe scoliosis with an AUC of 0.873, sensitivity 0.188, specificity 1.00, accuracy 0.936, positive prediction value 1 and a negative prediction value 0.935. Using the standardized integral area as an independent variable and the Cobb angle as a dependent variable, a linear regression equation was established as Cobb angle = 13.36 + 70.54 × Standardized area, the model has statistical significance. In conclusion, the integrated area algorithm method of machine learning can quickly and efficiently assess the degree of scoliosis and is suitable for screening the degree of scoliosis in a large dataset as a useful supplement to the fine measurement of scoliosis Cobb angle.