PLoS ONE (Jan 2024)
Diagnostic role of Sysmex hematology analyzer in the detection of malaria: A systematic review and meta-analysis.
Abstract
BackgroundMalaria control depends primarily on rapid and accurate diagnosis followed by successful treatment. Light microscopy is still used as a gold standard method for the diagnosis of malaria. The Sysmex hematology analyzer is a novel method for malaria detection. Therefore, the aim of this review was to investigate the diagnostic accuracy of the Sysmex hematology analyzer for malaria diagnosis.MethodsElectronic databases like PubMed, PubMed Central, Science Direct databases, Google Scholar, and Scopus were used to find relevant articles from April to June 14, 2023. The studies' methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Using Review Manager 5.4.1, the estimates of sensitivity and specificity, as well as their 95% confidence intervals, were shown in forest plots. Midas software in Stata 14.0 was utilized to calculate the summary estimates of sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio. Heterogeneity was assessed by using I2 statistics. In addition, publication bias was assessed using a funnel plot and Deeks' test. Sub-group and meta- regression analysis were also performed.ResultsA total of 15 studies were assessed for diagnostic accuracy. The sensitivity and specificity of Sysmex hematology analyzer for studies ranged from 46% to 100% and 81% to 100%, respectively. The summary estimate of sensitivity and specificity of Sysmex hematology analyzer were 95% (95% CI: 85%-99%) and 99% (95% CI: 97%-100%), respectively. It had excellent diagnostic accuracy. There were significant heterogeneity among the studies included in this meta-analysis. The summary estimate of sensitivity and specificity of Sysmex hematology analyzer using polymerase chain reaction as the gold standard was 97.6% (95% CI: 83.2, 99.7) and 99.4% (98.5, 99.8), respectively.ConclusionIn this review, Sysmex hematology analyzer had excellent diagnostic accuracy. Therefore, it could be used as an alternate diagnostic tool for malaria diagnosis in the hospital and health center.Trial registrationSystematic review registration PROSPERO (2023: CRD42023427713). https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42023427713.