IEEE Access (Jan 2021)

Typhoon Inversion Method Combined With the YanMeng Wind Field and a Meteorological Monitoring System for Transmission Lines

  • Liqiang An,
  • Yongyu Guan,
  • Zhijian Zhu,
  • Jingli Liu,
  • Zhuobo Niu

DOI
https://doi.org/10.1109/ACCESS.2020.3044419
Journal volume & issue
Vol. 9
pp. 619 – 630

Abstract

Read online

Extreme weather like typhoon leaves significantly terrible influence on the stability of power grid in the coastal area. A high-voltage transmission line includes hundreds of towers and usually stretches hundreds of kilometers. It is not economical to install typhoon monitoring system throughout the transmission line. This paper proposes a typhoon inversion method (TIM) for transmission line which utilizes engineering wind field model and only requires monitoring data from a few towers. The developed method is called YanMeng wind field (YM) with directional mutation genetic algorithm (DMGA) for transmission lines, or YM-DMGA method. DMGA utilizes real-time monitoring data, and improves simulation accuracy of average wind speed by dynamically optimizing two critical parameters $B$ and $z_{0}$ in wind field model, which is a great improvement over the traditional YM model relying on historical data. The TIM is mainly composed of three parts, the meteorological monitoring system (MMS), the YM-DMGA model, and the software system. The TIM collects real-time measured wind data of particular monitoring stations through the MMS. Meanwhile, wind data of the whole transmission line is simulated using the YM-DMGA and displayed by the software system. Then the method proposed is verified to be effective in three aspects. First of all, the YM-DMGA method has great enhancement in accuracy, for the coefficient of determination $R_{square}$ increases from 0.811 to 0.986. Secondly, DMGA in the method has quicker convergent speed than typical GA, with fitness converged in the 269th epoch, earlier than that for typical GA, 656th epoch. Lastly, DMGA has better optimal fitness value of 0.6239, bigger than that of typical GA, 0.5891. At the end of the paper, an application of the method to an 110kV double-circuit transmission line is presented to reveal the risk under the impact of the super typhoon Rammasun.

Keywords