Journal of Intensive Care (Feb 2023)

The time cost of physiologically ineffective intravenous fluids in the emergency department: an observational pilot study employing wearable Doppler ultrasound

  • Jon-Émile S. Kenny,
  • Stanley O. Gibbs,
  • Delaney Johnston,
  • Zhen Yang,
  • Lisa M. Hofer,
  • Mai Elfarnawany,
  • Joseph K. Eibl,
  • Amanda Johnson,
  • Anthony J. Buecker,
  • Vivian C. Lau,
  • Benjamin O. Kemp

DOI
https://doi.org/10.1186/s40560-023-00655-6
Journal volume & issue
Vol. 11, no. 1
pp. 1 – 9

Abstract

Read online

Abstract Background Little data exist on the time spent by emergency department (ED) personnel providing intravenous (IV) fluid to ‘responsive’ versus ‘unresponsive’ patients. Methods A prospective, convenience sample of adult ED patients was studied; patients were enrolled if preload expansion was indicated for any reason. Using a novel, wireless, wearable ultrasound, carotid artery Doppler was obtained before and throughout a preload challenge (PC) prior to each bag of ordered IV fluid. The treating clinician was blinded to the results of the ultrasound. IV fluid was deemed ‘effective’ or ‘ineffective’ based on the greatest change in carotid artery corrected flow time (ccFT∆) during the PC. The duration, in minutes, of each bag of IV fluid administered was recorded. Results 53 patients were recruited and 2 excluded for Doppler artifact. There were 86 total PCs included in the investigation comprising 81.7 L of administered IV fluid. 19,667 carotid Doppler cardiac cycles were analyzed. Using ccFT∆ ≥ + 7 ms to discriminate ‘physiologically effective’ from ‘ineffective’ IV fluid, we observed that 54 PCs (63%) were ‘effective’, comprising 51.7 L of IV fluid, whereas, 32 (37%) were ‘ineffective’ comprising 30 L of IV fluid. 29.75 total hours across all 51 patients were spent in the ED providing IV fluids categorized as ‘ineffective.’ Conclusions We report the largest-known carotid artery Doppler analysis (i.e., roughly 20,000 cardiac cycles) in ED patients requiring IV fluid expansion. A clinically significant amount of time was spent providing physiologically ineffective IV fluid. This may represent an avenue to improve ED care efficiency.

Keywords