Sensors (Sep 2021)

Use of the Ferroelectric Ceramic Bismuth Titanate as an Ultrasonic Transducer for High Temperatures and Nuclear Radiation

  • Brian T. Reinhardt,
  • Bernhard R. Tittmann

DOI
https://doi.org/10.3390/s21186094
Journal volume & issue
Vol. 21, no. 18
p. 6094

Abstract

Read online

Ultrasonic transducers are often used in the nuclear industry as sensors to monitor the health and process status of systems or the components. Some of the after-effects of the Fukushima Daiichi earthquake could have been eased if sensors had been in place inside the four reactors and sensed the overheating causing meltdown and steam explosions. The key element of ultrasonic sensors is the piezoelectric wafer, which is usually derived from lead-zirconate-titanate (Pb(Zr, Ti)O3, PZT). This material loses its piezoelectrical properties at a temperature of about 200 °C. It also undergoes nuclear transmutation. Bismuth titanate (Bi4Ti3O12, BiTi) has been considered as a potential candidate for replacing PZT at the middle of this temperature range, with many possible applications, since it has a Curie–Weiss temperature of about 650 °C. The aim of this article is to describe experimental details for operation in gamma and nuclear radiation concomitant with elevated temperatures and details of the performance of a BiTi sensor during and after irradiation testing. In these experiments, bismuth titanate has been demonstrated to operate up to a fast neutron fluence of 5 × 1020 n/cm2 and gamma radiation of 7.23 × 1021 (gamma/cm2). The results offer a perspective on the state-of the-art for a possible sensor for harsh environments of high temperature, Gamma radiation, and nuclear fluence.

Keywords