Haematologica (Aug 2009)

Reduced CD38 expression on CD34+ cells as a diagnostic test in myelodysplastic syndromes

  • Nicolas Goardon,
  • Emmanouil Nikolousis,
  • Alexander Sternberg,
  • Wai-Kit Chu,
  • Charles Craddock,
  • Peter Richardson,
  • Richard Benson,
  • Mark Drayson,
  • Graham Standen,
  • Paresh Vyas,
  • Sylvie Freeman

DOI
https://doi.org/10.3324/haematol.2008.004085
Journal volume & issue
Vol. 94, no. 8

Abstract

Read online

Diagnosis of myelodysplastic syndrome can be difficult especially in cases with a low blast count and a normal karyotype. Flow cytometry has been used to distinguish myelodysplastic syndrome from non-clonal cytopenias. No one single simple flow cytometric parameter has been proposed to be diagnostic of myelodysplastic syndrome. We have studied samples from 100 myelodysplastic syndrome patients and as control samples; 70 non-clonal cytopenias, 5 subjects with normal hematology, 31 patients with acute myeloid leukemia and 11 with chronic myelomonocytic leukemia or myeloproliferative disorder. We show that reduced relative mean fluorescence of CD38 below a threshold value on CD34+ cells diagnosed low-grade myelodysplastic syndrome with 95% sensitivity (95% confidence interval, 87–99%) and 92% specificity (95% confidence interval, 82–97%). This simple flow cytometric test may be of value in the routine clinical diagnosis of myelodysplastic syndrome, especially in cases with a low blast count and normal karyotype.