International Journal of COPD (Oct 2021)

Effect of Endobronchial Coils on Exercise Tolerance and Lung Functions in Patients with Severe Emphysema – A Retrospective Cohort Study of 48 Patients

  • Pertzov B,
  • Soliman M,
  • Shostak Y,
  • Heching M,
  • Rosengarten D,
  • Izbicki G,
  • Kramer MR

Journal volume & issue
Vol. Volume 16
pp. 2809 – 2815

Abstract

Read online

Barak Pertzov,1,2 Maysaa Soliman,2 Yael Shostak,1,2 Moshe Heching,1,2 Dror Rosengarten,1,2 Gabriel Izbicki,3,4,* Mordechai Reuven Kramer1,2,* 1Pulmonary Division, Rabin Medical Center, Petach Tikva, Israel; 2Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel; 3Pulmonary Institute, Shaare Zedek Medical Center, Jerusalem, Israel; 4Hebrew University-Hadassah Medical School, Jerusalem, Israel*These authors contributed equally to this workCorrespondence: Barak PertzovPulmonary Division, Rabin Medical Center, Petach Tikva, IsraelTel +972-3-9377221/3Fax +972-3-9242091Email [email protected]: Lung volume reduction with endobronchial coils treatment (ECT), for patients with severe emphysema, has shown modest improvement in exercise capacity and lung functions in clinical trials, yet the benefit of this procedure is still unclear.Methods: We conducted a multicenter retrospective cohort study including all patients who underwent ECT in Israel and a propensity score matched control group of patients with chronic obstructive pulmonary disease (COPD) that were treated with usual care. The primary outcome was six-minute walk test distance (6MWTD), secondary outcomes were lung function tests and patient survival.Results: Overall, 46 patients were included in the ECT group. Their mean 6MWTD at baseline and at 6 and at 24 months post procedure was 331.0± 101.4, 372.9± 76.8 and 338.8± 104.8, respectively (overall P=0.04, pairwise comparison: baseline to 6 months (P=0.1), baseline to 24 months (P=1.0)). Mean FEV1 values at baseline and at 6 and at 24 months post procedure were 0.86± 0.38, 0.92± 0.37 and 0.82± 0.36 liters, respectively (overall P=0.003, pairwise comparison: baseline to 6 months (P=0.04), baseline to 24 months (P=0.75)). The median 6MWTD for the ECT and control groups at 24 months were 333.0 (262.5– 390) and 280 (210– 405), respectively (P=0.16). There was no difference in overall survival (P=0.84). Heterogenous emphysema was a significant predictor of treatment success in univariate analysis (p=0.004).Conclusion: Lung volume reduction with endobronchial coils may improve the exercise capacity and FEV1 of COPD patients. However, the majority of the effect was diminished after 24 months. The current state of evidence does not support regulatory approval of ECT and warrant its use only after consideration of the benefit-harm ratio in a highly selected patient population.Keywords: emphysema, endobronchial coils, lung volume reduction, six-minute walk, residual volume, FEV1, survival

Keywords