Journal of International Medical Research (Jun 2020)

Role of diffusion-weighted imaging in the diagnosis of cerebral venous thrombosis

  • Bin Lv,
  • Cheng-lin Tian,
  • Xiang-yu Cao,
  • Xin-feng Liu,
  • Jun Wang,
  • Sheng-yuan Yu

DOI
https://doi.org/10.1177/0300060520933448
Journal volume & issue
Vol. 48

Abstract

Read online

Objective To evaluate the hyperintense signal (HIS) performance on diffusion-weighted imaging (DWI) in diagnosing cerebral venous thrombosis (CVT). Methods Seventy-eight patients with CVT hospitalized from January 2004 to January 2015 were retrospectively studied alongside 78 controls without intracranial organic diseases. Diagnostic accuracy indices of HIS on DWI or T2-weighted imaging (T2WI) to diagnose CVT at different sites and states were analyzed. Results The overall sensitivity of HIS on DWI for the diagnosis of CVT was significantly lower than that of HIS on T2WI (34.6% vs. 79.5%). HIS on T2WI was more sensitive than HIS on DWI in detecting thrombosis, especially in the superior sagittal sinus and transverse sinus. HIS on DWI was inversely related to the time between disease onset and imaging. Compared with HIS on T2WI, combining HIS on DWI and T2WI did not increase the sensitivity for detecting CVT. HIS on DWI was not detected in the control group, but HIS on T2WI was detected in 26.3% of control individuals. The specificity of HIS on DWI for CVT was higher than that of HIS on T2WI (97.4% vs. 76.9%). Conclusion HIS on DWI has a lower sensitivity, but a higher specificity, than HIS on T2WI for diagnosing CVT.