International Journal of Emergency Medicine (Jan 2024)

The diagnostic accuracy of point-of-care ultrasound parameters for airway assessment in patients undergoing intubation in emergency department—an observational study

  • Aadya Pillai,
  • Poonam Arora,
  • Ankita Kabi,
  • Udit Chauhan,
  • Reshma Asokan,
  • P. Akhil,
  • Takshak Shankar,
  • D. J. Lalneiruol,
  • Himanshi Baid,
  • Hannah Chawang

DOI
https://doi.org/10.1186/s12245-024-00585-6
Journal volume & issue
Vol. 17, no. 1
pp. 1 – 11

Abstract

Read online

Abstract Background Endotracheal intubation is an essential resuscitative procedure in the emergency setting. Airway assessment parameters such as the Mallampati classification are difficult to perform in an emergency setting. As point-of-care ultrasound (POCUS) assessment of airway parameters does not require patients to perform any mandatory action, ultrasound may become the potential first-line noninvasive airway assessment tool in the emergency department (ED). The use of POCUS in the ED has not been sufficiently studied. Using POCUS in airway assessment for predicting difficult intubation may be the next step in successful airway management. Methodology The study was an observational study conducted at the ED of the All India Institute of Medical Sciences (Rishikesh). The treating emergency physician recorded the patient history and systemic examination along with an indication for intubation. The POCUS assessment of airway parameters pre-epiglottis to epiglottic vocal cord ratio (Pre-E/E-VC), tongue thickness, hyomental distance, and distance from skin to the hyoid bone was performed by the study investigator. During laryngoscopy, Cormack-Lehane (CL) grading was assessed. The data was entered and analyzed. Results Seventy patients who required intubation in the ED were enrolled in the study. Among the study population, 48.6%, 28.6%, 14.3%, 1.4%, and 7.1% were classified with the following CL grading: 1, 2a, 2b, 3a, and 3b, respectively. At a cutoff of ≥ 1.86, Pre-E/E-VC predicts difficult laryngoscopy (AUC 0.835) with a sensitivity of 83% and a specificity of 94%. At a cutoff of ≥ 5.98 cm, tongue thickness predicts difficult laryngoscopy (AUC 0.78) with a sensitivity of 83% and a specificity of 88%. At a cutoff of hyomental distance ≤ 6 cm, it predicts difficult laryngoscopy with a sensitivity of 83% and a specificity of 88%. All parameters can act as a promising tool for predicting difficult laryngoscopy, with the single best parameter being Pre-E/E-VC. Conclusion Assessment of the airway with POCUS may be helpful to the emergency physician when the clinical airway assessment parameters fail to predict difficult laryngoscopy as most patients requiring intubation are uncooperative. Assessment of the parameters in our study Pre-E/E-VC, tongue thickness, and hyomental distance can act as a promising tool for predicting difficult laryngoscopy in the emergency scenario.

Keywords