Applied Sciences (Aug 2023)

Influence Analysis of Liquefiable Interlayer on Seismic Response of Underground Station Structure

  • Jiantao Yao,
  • Yongliang Lin

DOI
https://doi.org/10.3390/app13169210
Journal volume & issue
Vol. 13, no. 16
p. 9210

Abstract

Read online

To study the influence law of the seismic response of underground station structures at liquifiable interlayer sites, a two-dimensional numerical model of the interaction between the soil and station structure was established based on the finite difference software FLAC3D. The nonlinear dynamic response of the station structure located at the liquifiable interlayer site was analyzed considering the location distribution, relative density, and thickness of the liquifiable interlayer. The results show that the deformation of the structure is greatest when the liquifiable interlayer is distributed on both sides of the station side walls, while the interlayer has an energy-dissipating and damping effect on the upper station structure when it is located at the bottom of the structure. The lower the relative density of the liquifiable interlayer is, the stronger the internal dynamic response of the structure will be, and the more unfavorable it will be to the seismic resistance of the structure. When the liquefiable interlayer is only present in the lateral foundation of the station, an increase in its thickness results in a stronger shear effect on the structure and a higher probability of damage. However, when the thickness of the liquifiable interlayer reaches a point where the entire station is placed within it, the lateral force and deformation of the structure are significantly reduced.

Keywords