Case Reports in Gastrointestinal Medicine (Jan 2013)

A Case of Secondary Aortoesophageal Fistula Inserted a Covered Self-Expanding Esophageal Stent to Control Gastrointestinal Bleeding

  • Makoto Onodera,
  • Yoshihiro Inoue,
  • Yasuhisa Fujino,
  • Satoshi Kikuchi,
  • Shigeatsu Endo

DOI
https://doi.org/10.1155/2013/857135
Journal volume & issue
Vol. 2013

Abstract

Read online

A 73-year-old man presented with melena. After a thorough workup including esophageal endoscopy, computed tomography scans, and esophagography, the diagnosis of secondary aortoesophageal fistula was made. Two years previously, he had undergone endovascular stent-graft repair for the dissection of his descending thoracic aorta. Because of the generally poor condition of the patient and the high risk of any aggressive surgical intervention, we inserted a covered self-expanding esophageal stent on postadmission day 18. Esophagography after insertion did not show any evidence of a leak of contrast medium. Despite treatment with antibiotics, he developed sepsis and expired on day 52, but rebleeding did not occur in this period. We consider insertion of a covered self-expanding esophageal stent as a feasible option in the management of secondary aortoesophageal fistula in high-risk patients.