Cardiovascular Ultrasound (Nov 2012)
Midwall ejection fraction for assessing systolic performance of the hypertrophic left ventricle
Abstract
Abstract Background In patients with left ventricular hypertrophy (LVH), LV midwall fractional shortening (FS) is used as a measure of LV systolic performance that is more physiologically appropriate than conventional FS. For evaluation of LV volume and ejection fraction (EF), 2-dimensional (2D) echocardiography is more accurate than M-mode echocardiography. The purpose of this study was to assess systolic performance by midwall EF using 2D speckle tracking echocardiography (STE). Methods Sixty patients were enrolled in the study. Patients were divided into two groups with LVH (n = 30) and without LVH (control group, n = 30). LV systolic function was compared between the two groups and the relationships of left ventricular mass index (LVMI) with LV systolic parameters, including midwall EF, were investigated. Results Midwall EF in the LVH group was significantly lower than that in the control group (42.8±4.4% vs. 48.1±4.1%, p Conclusions These results show that midwall EF can be determined using 2D STE. Midwall EF can be used to monitor LV systolic dysfunction, which is not possible with conventional EF. Evaluation of midwall EF may allow assessment of new parameters of LV systolic function in patients with LV geometric variability.
Keywords