JACC: Case Reports (Feb 2024)

Hybrid Stent Implantation Into Right Ventricular Outflow Tract in a Newborn With Tetralogy of Fallot

  • Grzegorz Zalewski, MD,
  • Michał Buczyński, MD,
  • Michał Zawadzki, MD,
  • Paulina Kopacz, MD,
  • Jacek Kuźma, MD

DOI
https://doi.org/10.1016/j.jaccas.2023.102172
Journal volume & issue
Vol. 29, no. 3
p. 102172

Abstract

Read online

A case is presented of a newborn with tetralogy of Fallot and aortic coarctation. Progressive right ventricular outflow tract (RVOT) obstruction required urgent surgical therapy. Coronary artery crossing the outflow tract made ventriculotomy impossible. Hybrid RVOT stent implantation was performed, providing effective pulmonary flow and enabling postponing of corrective jumping graft implantation.

Keywords