Clinical, Cosmetic and Investigational Dentistry (Dec 2021)

Comparison of Fracture Resistance of Primary Incisors Restored with Different Intracanal-Reinforcement Materials

  • Salama F,
  • Abdelmegid F,
  • Alhussain M,
  • Muaddi H,
  • AlMaflehi N,
  • Alhowaish L

Journal volume & issue
Vol. Volume 13
pp. 507 – 512

Abstract

Read online

Fouad Salama,1 Faika Abdelmegid,2 Mohammed Alhussain,3 Hasan Muaddi,3 Nassr AlMaflehi,4 Latifa Alhowaish1 1Department of Pediatric Dentistry and Orthodontics, College of Dentistry, King Saud University, Riyadh, Saudi Arabia; 2Department of Oral Medicine and Diagnostic Sciences, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia; 3College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia; 4Department of Periodontics and Community Dentistry, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi ArabiaCorrespondence: Latifa Alhowaish Email [email protected]: To evaluate the effects of placing short posts made of different restorative materials on the fracture resistance of root canals in primary incisors of primary teeth.Materials and Methods: The root canals of 40 extracted primary incisors were prepared and filled with Vitapex and randomly divided into five groups of 8 each. In Groups 1– 4, a post space was created and filled with different restorative materials (Tetric® N-Ceram Bulk Fill, AeliteFlo, Filtek Z250 XT, and GC Fuji II LC® capsule), while Group 5 was kept filled with Vitapex as a control. Fracture resistance was measured using a universal testing machine at a 0.5-mm/min crosshead speed. The results were statistically analyzed and compared.Results: The highest fracture resistance was recorded for GC Fuji II LC capsules [439.82 N] and control [423.37 N], while the lowest fracture resistance was recorded for Tetric® N Ceram Bulk Fill (239.91 N). A multiple comparison test showed that the Tetric® N-Ceram Bulk Fill had a significantly lower average value than AeliteFlo (P = 0.030), as well as a significantly lower average value than GC Fuji II LC® capsule (P = 0.001), and a significantly lower average value than the control group (P = 0.002). Multiple comparison tests showed no significant difference between Tetric® N-Ceram Bulk Fill and Filtek Z250 XT (P = 0.39).Conclusion: The fracture resistance of primary incisor root canals differs according to the material used for the intracanal posts. Three-millimeter intracanal posts in the primary incisors showed the highest fracture resistance for the teeth restored with GC Fuji II LC capsules and the control.Keywords: fracture resistance, intracanal posts, primary incisors, resin composite

Keywords