Communications Engineering (Jun 2025)

3D transcranial ultrasound localization microscopy in awake mice: protocol and open-source pipeline

  • Georges Chabouh,
  • Louise Denis,
  • Myriam Abioui-Mourgues,
  • Jean-Baptiste Deloges,
  • Jacques Battaglia,
  • Arthur Chavignon,
  • Baptiste Heiles,
  • Basile Pradier,
  • Sylvain Bodard,
  • Denis Vivien,
  • Cyrille Orset,
  • Olivier Couture

DOI
https://doi.org/10.1038/s44172-025-00415-4
Journal volume & issue
Vol. 4, no. 1
pp. 1 – 8

Abstract

Read online

Abstract We present an open-source code for 3D super-resolution ultrasound imaging. Open-3DULM was applied to transcranial imaging in habituated awake mice. Comparative analysis reveals that isoflurane anesthesia induces significant vasodilation and increased cerebral blood flow (CBF) in veins, while only a subset of arteries exhibits these effects compared to the awake state. This method could serve as a reference for developing new types of 3D vascular quantifications, particularly emphasizing the importance of awake and 3D imaging for accurate cerebral blood flow measurement in neuroscience research.