Journal of Pharmacy and Bioallied Sciences (Jan 2013)

Determination of galantamine hydrobromide in bulk drug and pharmaceutical dosage form by spectrofluorimetry

  • Amit V Patel,
  • Vishal J Patel,
  • Avani V Patel,
  • Jayant B Dave,
  • Chhaganbhai N Patel

DOI
https://doi.org/10.4103/0975-7406.120079
Journal volume & issue
Vol. 5, no. 4
pp. 314 – 317

Abstract

Read online

Aim: To develop a simple, accurate, sensitive, rapid and precise method for the determination of galantamine hydrobromide in bulk drug and pharmaceutical dosage form. Material and Methods: The method employs wavelength detection and determination of galantamine hydrobromide at excitation wavelength 282 nm and emission wavelength 607 nm in a solution of simple distilled water. Result and Conclusion: The method was found to be linear in the range of 2-14 μg/ml having r2 = 0.9999. The mean accuracy was found to be 98.12% to 99.67%. The intraday and interday precision was found to be 0.18-0.35% and 0.13-0.46%, respectively. The limit of detection was found to be 0.29 μg/ml. The limit of quantification was found to be 0.89 μg/ml. The method was successfully applied for the determination of galantamine hydrobromide in bulk drug as well as pharmaceutical dosage form.

Keywords