BMC Ophthalmology (Jan 2023)

Corneal biomechanical characteristics following small incision lenticule extraction for myopia and astigmatism with 3 different cap thicknesses

  • Xiaotong Lv,
  • Fengju Zhang,
  • Yanzheng Song,
  • Changbin Zhai,
  • Ning Guo,
  • Lingbo Lai,
  • Yushan Xu

DOI
https://doi.org/10.1186/s12886-023-02786-8
Journal volume & issue
Vol. 23, no. 1
pp. 1 – 9

Abstract

Read online

Abstract Background The design of cap thickness for small incision lenticule extraction (SMILE) plays a role in post-laser vision correction (post-LVC) corneal biomechanics. This study aimed to compare the corneal biomechanical characteristics following SMILE with different cap thicknesses of 110 μm, 120 μm, and 130 μm for myopia and myopic astigmatism correction. Methods Seventy-five patients (146 eyes) who underwent SMILE with designed cap thickness of 110 μm, 120 μm, and 130 μm were recruited at the Eye Center of Beijing Tongren Hospital between August 2020 and November 2021. Visual acuity, refraction, and corneal biomechanical parameters were measured preoperatively, 1 week and 1, 3, 6 months postoperatively. One-way analysis of variances (ANOVA) with Bonferroni correction or Kruskal-Wallis test was performed to compare the parameters among different groups. Repeated-measures analysis of variance with Bonferroni correction or Friedman test was applied for comparing the parameters within different follow-up times. Results Uncorrected distance visual acuity of 110-μm group was better only at 1-week and 1-month postoperatively (P = 0.012, 0.037). There were no significant differences in spherical equivalent, nor in Corvis biomechanical index-laser vision correction (CBI-LVC). All the parameters reached stability at 3-month postoperatively. Integrated radius (IR) and deformation amplitude ratio 2 mm (DA ratio 2 mm) in 120-μm and 130-μm groups were higher than 110-μm group at 1-month postoperatively (P = 0.019, 0.002). So was Ambrósio relational thickness (ARTh) at 6-month postoperatively (P = 0.011). Stiffness parameter at applanation A1 (SP-A1), stress-strain index (SSI), biomechanically corrected intraocular pressure (bIOP) and central corneal thickness (CCT) were highest in 130-μm group, followed by 120-μm group, then 110-μm group at 3-month (P<0.001, P = 0.030, P = 0.027, P = 0.008) and 6-month (P<0.001, P = 0.002, P = 0.0023, P = 0.001) postoperatively. Conclusions The corneal stiffness following SMILE was greatest with 130-μm cap, followed by 120-μm cap, then 110-μm cap. 130-μm cap might have advantages in terms of corneal biomechanics and retreatment option. The SMILE-designed protocol should be customized in practice.

Keywords