Micromachines (Nov 2021)

Development of a Microfluidic Device to Form a Long Chemical Gradient in a Tissue from Both Ends with an Analysis of Its Appearance and Content

  • Yasunori Tokuoka,
  • Keiichi Kondo,
  • Noboru Nakaigawa,
  • Tadashi Ishida

DOI
https://doi.org/10.3390/mi12121482
Journal volume & issue
Vol. 12, no. 12
p. 1482

Abstract

Read online

Tissue assays have improved our understanding of cancers in terms of the three-dimensional structures and cellular diversity of the tissue, although they are not yet well-developed. Perfusion culture and active chemical gradient formation in centimeter order are difficult in tissue assays, but they are important for simulating the metabolic functions of tissues. Using microfluidic technology, we developed an H-shaped channel device that could form a long concentration gradient of molecules in a tissue that we could then analyze based on its appearance and content. For demonstration, a cylindrical pork tissue specimen was punched and equipped in the H-shaped channel device, and both ends of the tissue were exposed to flowing distilled and blue-dyed water for 100 h. After perfusion, the tissue was removed from the H-shaped channel device and sectioned. The gradient of the blue intensity along the longitudinal direction of the tissue was measured based on its appearance and content. We confirmed that the measured gradients from the appearance and content were comparable.

Keywords