International Journal of Cardiology. Cardiovascular Risk and Prevention (Mar 2023)
Blood pressure changes during routine transthoracic echocardiography
Abstract
Background: Increased afterload affects many of the flow dependent metrics assessed during transthoracic echocardiography (TTE) especially in the evaluation valvular disease. A single timepoint blood pressure (BP) may not accurately reflect the afterload present at the time of flow-dependent imaging and quantification. We assessed the magnitude of change in BP at discrete timepoints during routine TTE. Method: We conducted a prospective study where participants underwent automated BP measurement while undergoing a clinically indicated TTE. The first reading was obtained right after the patient lay supine and subsequent readings were taken at 10-min intervals during image acquisition. Result: We included 50 participants (66% were male, with a mean age of 64 years). After 10 min, 40 (80%) participants had a drop in systolic BP of >10 mmHg. Compared to the baseline, there was a significant drop in systolic BP (mean decrease 20.0 ± 12.8 mmHg; P < 0.05), and diastolic BP (mean decrease 15.7 ± 13.2 mmHg; P < 0.05) at 10 min. The systolic BP remained different from the baseline value throughout the duration of the study (average decrease from baseline to study end was 12.4 ± 16.0 mmHg, p < 0.05). Conclusion: BP recorded just prior to TTE does not accurately reflect the afterload present during most of the study. This finding has important implications for valvular heart disease imaging protocols that incorporate flow dependent metrics, where the presence or absence of hypertension may lead to under- or over-estimation of disease severity.