Journal of Pipeline Science and Engineering (Jun 2023)
Investigation on utilizing pulse CP in a city gas station: A comparison with conventional CP
Abstract
In this study, a pulse Cathodic Protection (CP) rectifier was designed and made. The performance of the pulse rectifier was monitored and compared with a conventional system. In this regard, different values of duty cycle (73% and 50%) and frequency (50 kHz and 60 kHz) were analyzed. Results showed that the AC voltage and current consumption dramatically dropped compared to the conventional rectifier. Also, the pulse CP protection potential was distributed more uniformly as a function of pulse parameters in the optimum combination of 50 kHz and 73% for frequency and duty cycle, respectively. This was explained by the changes in the electrochemical polarization resistance of the environment when utilizing the pulse CP.