Current Oncology (Nov 2022)
Efficacy and Accuracy of Using Magnetic Seed for Preoperative Non-Palpable Breast Lesions Localization: Our Experience with Magseed
Abstract
In this retrospective study we share our single-center experience using a magnetic seed for the preoperative localization of non-palpable breast lesions. Patients who underwent a preoperative localization with Magseed® (Endomagnetics, Cambridge, UK) placement between 2020 and 2022 were enrolled. Indications to Magseed placement have been established during multidisciplinary meetings prior to surgery and all patients underwent breast-conserving surgery (BCS). 45 patients were included. Magnetic seeds have been introduced under ultrasound guidance in 40 patients (88.9%) and under stereotactic guidance in 5 patients (11.1%). We registered a highly successful placement rate (97.8%), with only one case of migration (2.2%). After BCS, all the magnetic seeds were recovered (100% retrieval rate). The re-excision rate for positive margins was 0%. Our experience, with a highly successful placement and retrieval rate and a re-excision rate equal to 0%, is consistent with the encouraging literature published on Magseed so far, suggesting this technique to be extremely effective. Moreover, our single case of seed migration supports the existing data stating that Magseed migration is rare. In conclusion, despite acknowledging Magseed limitations, we highly value the advantages linked to this technique, and we, therefore, uphold its use.
Keywords