Patient Safety in Surgery (May 2024)

The clinical relevance of fixation failure after pubic symphysis plating for anterior pelvic ring injuries: an observational cohort study with long-term follow-up

  • Dmitry Notov,
  • Eva Knorr,
  • Ulrich J.A. Spiegl,
  • Georg Osterhoff,
  • Andreas Höch,
  • Christian Kleber,
  • Philipp Pieroh

DOI
https://doi.org/10.1186/s13037-024-00401-3
Journal volume & issue
Vol. 18, no. 1
pp. 1 – 7

Abstract

Read online

Abstract Background Open reduction and plate fixation is a standard procedure for treating traumatic symphyseal disruptions, but has a high incidence of implant failure. Several studies have attempted to identify predictors for implant failure and discussed its impact on functional outcome presenting conflicting results. Therefore, this study aimed to identify predictors of implant failure and to investigate the impact of implant failure on pain and functional outcome. Methods In a single-center, retrospective, observational non-controlled cohort study in a level-1 trauma center from January 1, 2006, to December 31, 2017, 42 patients with a plate fixation of a traumatic symphyseal disruption aged ≥ 18 years with a minimum follow-up of 12 months were included. The following parameters were examined in terms of effect on occurrence of implant failure: age, body mass index (BMI), injury severity score (ISS), polytrauma, time to definitive treatment, postoperative weight-bearing, the occurrence of a surgical site infection, fracture severity, type of posterior injury, anterior and posterior fixation. A total of 25/42 patients consented to attend the follow- up examination, where pain was assessed using the Numerical Rating Scale and functional outcome using the Majeed Pelvic Score. Results Sixteen patients had an anterior implant failure (16/42; 37%). None of the parameters studied were predictive for implant failure. The median follow-up time was six years and 8/25 patients had implant failure. There was no difference in the Numerical Rating Scale, but the work-adjusted Majeed Pelvic Score showed a better outcome for patients with implant failure. Conclusion implant failure after symphyseal disruptions is not predictable, but appears to be clinically irrelevant. Therefore, an additional sacroiliac screw to prevent implant failure should be critically discussed and plate removal should be avoided in asymptomatic patients.

Keywords