Sensors (Jan 2025)

Estimation of the Measurement Accuracy of Wireless Passive Resonance Sensors

  • Leonhard M. Reindl,
  • Taimur Aftab,
  • Thomas Schaechtle,
  • Thomas Ostertag,
  • Wei Luo,
  • Stefan Johann Rupitsch

DOI
https://doi.org/10.3390/s25030747
Journal volume & issue
Vol. 25, no. 3
p. 747

Abstract

Read online

Resonators are passive devices that respond to an excitation signal by oscillating at their natural frequency with exponentially decreasing amplitudes. Physical, chemical and electrical variables can modify the natural frequencies of resonators. If resonators are connected to antennas or other transducers that couple into a communication channel, they enable purely passive sensors that can be read wirelessly. In this manuscript, we use maximum likelihood estimation to analyze the measurement accuracy that can be achieved by the wireless readout of passive resonant sensors as a function of the read signal, the stimulation power and noise figure of the reader, the distance and transducer gain of the transmission channel, and the natural frequency and quality factor of the resonant passive sensor. The Crámer–Rao lower bound characterizes the minimum variance of the natural frequency and decay constant of the resonator. We show the derivation of the Crámer–Rao lower bounds from the Fisher information matrix based on a maximum likelihood estimation of discrete-time samples of an exponentially decaying phasor. This theoretical lower limit of accuracy is almost achieved by an iterative algorithm that approximates the maximum of the measured resonator spectrum with a Lorentz curve.

Keywords