Sensors (Oct 2019)

Meander-Line Slot-Loaded High-Sensitivity Microstrip Patch Sensor Antenna for Relative Permittivity Measurement

  • Junho Yeo,
  • Jong-Ig Lee

DOI
https://doi.org/10.3390/s19214660
Journal volume & issue
Vol. 19, no. 21
p. 4660

Abstract

Read online

A high-sensitivity microstrip patch sensor antenna (MPSA) loaded with a meander-line slot (MLS) is proposed for the measurement of relative permittivity. The proposed MPSA was designed by etching the MLS along the radiating edge of the patch antenna, and it enhanced the relative permittivity sensitivity with an additional effect of miniaturization in the patch size by increasing the slot length. The sensitivity of the proposed MPSA was compared with that of a conventional rectangular patch antenna and a rectangular slit (RS)-loaded MPSA, by measuring the shift in the resonant frequency of the input reflection coefficient. Three MPSAs were designed and fabricated on a 0.76 mm-thick RF-35 substrate to resonate at 2.5 GHz under unloaded conditions. Sensitivity comparison was performed by using five different standard dielectric samples with dielectric constants ranging from 2.17 to 10.2. The experiment results showed that the sensitivity of the proposed MPSA is 6.84 times higher for a low relative permittivity of 2.17, and 4.57 times higher for a high relative permittivity of 10.2, when compared with the conventional MPSA. In addition, the extracted relative permittivity values of the five materials under tests showed good agreement with the reference data.

Keywords