Buildings (Oct 2024)

Experimental Analysis of the Mechanical Behavior of Shear Connectors for Precast Sandwich Wall Panels When Subjected to the Push-Out Tests

  • John Kennedy Fonsêca Silva,
  • Rodrigo de Melo Lameiras

DOI
https://doi.org/10.3390/buildings14103246
Journal volume & issue
Vol. 14, no. 10
p. 3246

Abstract

Read online

Precast concrete sandwich panels consist of two outer layers connected by a central connector and an inner insulating layer that enhances thermal and acoustic performance. A key challenge with these panels is eliminating thermal bridges caused by metallic connectors, which reduce energy efficiency. PERFOFRP connectors, made from perforated glass fiber-reinforced polymer (GFRP) sheets, have been proposed to address this issue. These connectors feature holes that allow concrete to pass through, creating anchoring pins that enhance shear resistance and prevent the separation of the concrete layers. This research aimed to evaluate the effect of the diameter and number of holes on the mechanical strength of PERFOFRP connectors. Three diameters not previously reported in the literature were selected: 12.70 mm, 15.88 mm, and 19.05 mm. A total of 18 specimens, encompassing 6 different configurations with varying numbers of holes, underwent push-out tests. The most significant resistance increase was a 15% gain over non-perforated connectors, observed in the configuration featuring three holes of 19.05 mm. The connections exhibited rigid and nearly linear behavior until failure.

Keywords