International Journal of Biomedical Imaging (Jan 2024)

Super High Contrast USPIO-Enhanced Cerebrovascular Angiography Using Ultrashort Time-to-Echo MRI

  • Liam Timms,
  • Tianyi Zhou,
  • Ju Qiao,
  • Codi Gharagouzloo,
  • Vishala Mishra,
  • Rita Maria Lahoud,
  • John W. Chen,
  • Mukesh Harisinghani,
  • Srinivas Sridhar

DOI
https://doi.org/10.1155/2024/9763364
Journal volume & issue
Vol. 2024

Abstract

Read online

Background. Ferumoxytol (Ferahame, AMAG Pharmaceuticals, Waltham, MA) is increasingly used off-label as an MR contrast agent due to its relaxivity and safety profiles. However, its potent T2∗ relaxivity limits achievable T1-weighted positive contrast and leads to artifacts in standard MRI protocols. Optimization of protocols for ferumoxytol deployment is necessary to realize its potential. Methods. We present first-in-human clinical results of the Quantitative Ultrashort Time-to-Echo Contrast Enhanced (QUTE-CE) MRA technique using the superparamagnetic iron oxide nanoparticle agent ferumoxytol for vascular imaging of the head/brain in 15 subjects at 3.0T. The QUTE-CE MRA method was implemented on a 3T scanner using a stack-of-spirals 3D Ultrashort Time-to-Echo sequence. Time-of-flight MRA and standard TE T1-weighted (T1w) images were also collected. For comparison, gadolinium-enhanced blood pool phase images were obtained retrospectively from clinical practice. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and intraluminal signal heterogeneity (ISH) were assessed and compared across approaches with Welch’s two-sided t-test. Results. Fifteen volunteers (54±17 years old, 9 women) participated. QUTE-CE MRA provided high-contrast snapshots of the arterial and venous networks with lower intraluminal heterogeneity. QUTE-CE demonstrated significantly higher SNR (1707±226), blood-tissue CNR (1447±189), and lower ISH (0.091±0.031) compared to ferumoxytol T1-weighted (551±171; 319±144; 0.186±0.066, respectively) and time-of-flight (343±104; 269±82; 0.190±0.016, respectively), with p<0.001 in each comparison. The high CNR increased the depth of vessel visualization. Vessel lumina were captured with lower heterogeneity. Conclusion. Quantitative Ultrashort Time-to-Echo Contrast-Enhanced MR angiography provides approximately 5-fold superior contrast with fewer artifacts compared to other contrast-enhanced vascular imaging techniques using ferumoxytol or gadolinium, and to noncontrast time-of-flight MR angiography, for clinical vascular imaging. This trial is registered with NCT03266848.