Biosensors (Feb 2024)

Bidirectional and Stepwise Rotation of Cells and Particles Using Induced Charge Electroosmosis Vortexes

  • Shaoxi Wang,
  • Zhexin Zhang,
  • Xun Ma,
  • Yuanbo Yue,
  • Kemu Li,
  • Yingqi Meng,
  • Yupan Wu

DOI
https://doi.org/10.3390/bios14030112
Journal volume & issue
Vol. 14, no. 3
p. 112

Abstract

Read online

The rotation of cells is of significant importance in various applications including bioimaging, biophysical analysis and microsurgery. Current methods usually require complicated fabrication processes. Herein, we proposed an induced charged electroosmosis (ICEO) based on a chip manipulation method for rotating cells. Under an AC electric field, symmetric ICEO flow microvortexes formed above the electrode surface can be used to trap and rotate cells. We have discussed the impact of ICEO and dielectrophoresis (DEP) under the experimental conditions. The capabilities of our method have been tested by investigating the precise rotation of yeast cells and K562 cells in a controllable manner. By adjusting the position of cells, the rotation direction can be changed based on the asymmetric ICEO microvortexes via applying a gate voltage to the gate electrode. Additionally, by applying a pulsed signal instead of a continuous signal, we can also precisely and flexibly rotate cells in a stepwise way. Our ICEO-based rotational manipulation method is an easy to use, biocompatible and low-cost technique, allowing rotation regardless of optical, magnetic or acoustic properties of the sample.

Keywords