International Journal of Analytical Chemistry (Jan 2015)

Quantification of Niacin and Its Metabolite Nicotinuric Acid in Human Plasma by LC-MS/MS: Application to a Clinical Trial of a Fixed Dose Combination Tablet of Niacin Extended-Release/Simvastatin (500 mg/10 mg) in Healthy Chinese Volunteers

  • Pingping Zhang,
  • Yantong Sun,
  • Guobing Shi,
  • Yin Sui,
  • Qiuying Li,
  • Yunbiao Tang,
  • Jingkai Gu

DOI
https://doi.org/10.1155/2015/212437
Journal volume & issue
Vol. 2015

Abstract

Read online

Our paper aimed to develop rapid, sensitive, and specific LC-MS/MS method for the quantification of niacin (NA) and its metabolite nicotinuric acid (NUA) in human plasma. Following protein precipitation with acetonitrile, the NA, NUA, and internal standard (5-fluorouracil) were separated on a Zorbax 300SB-C8 column (250 mm × 4.6 mm, 5 μm) with a mobile phase consisting of methanol-2 mM ammonium acetate (3 : 97, v/v) at a flow rate of 1 mL/min (split 1 : 1). A tandem mass spectrometer equipped with electrospray ionization source was used as the detector and operated in negative ion mode. The linear concentration ranges of the calibration curves were 5–800 ng/mL for NA and NUA. The intra-assay RSD for quality control (QC) samples were from 5.0% to 8.7% for NA, and 5.5% to 7.6% for NUA. The interassay RSD for QC samples were from 2.8% to 9.4% for NA, and 3.7% to 5.8% for NUA. The relative errors for QC samples were from −2.2% to 2.3% for NA, and −0.6% to 3.2% for NUA. The method was successfully applied to the investigation of the pharmacokinetic profiles of NA, NUA in human after single dose administration of Niacin extended-release/Simvastatin tablet (500 mg/10 mg).