Revista de Odontologia da UNESP ()
Influence of diameter and intraradicular post in the stress distribution. Finite element analysis
Abstract
Abstract Introduction The biomechanical behavior of endodontically treated teeth depending on the selected restorative material and tooth situation to be restored. Objective To analyze by the two-dimensional finite element method the biomechanical behavior of different diameters in intraradicular posts and teeth with coronal remaining of 2mm. Material and method Six models were made with three types of posts, as follows: Glass fiber post, carbon fiber post, and cast metal post, both with diameter # 1 (1.1 mm in diameter) and # 2 (1.3 mm of diameter). The modeling was performed using the Rhinoceros 4.0 program. The FEMAP 10.2 and NEiNastran 9.2 programs were used to develop finite element models. The loading used was 100N for axial and oblique forces. The results were visualized using the von Mises stress map. The statistical analysis was made using analysis of variance (ANOVA) and Tukey post-test, with a significance level of 5%. Result The oblique loading stress values were higher than the axial loading (p<0.001) for both situations. The glass fiber post showed the lowest concentrations of stress on both loads (p<0.001). The carbon fiber post presented significant difference compared to the cast metal post, only in the oblique load (p=0.007). The diameter did not increase the stress of the evaluated posts (p=0.302). Conclusion The fiber posts were more favorable for restoration of endodontically treated teeth; the increase of diameter did not influence the increase of tension; the oblique load was more harmful for both posts and tooth structure.
Keywords