Photonics (Oct 2020)

A Refractive Index Sensitive Liquid Level Monitoring Sensor Based on Multimode Interference

  • Fan Zhang,
  • Shuguang Li,
  • Xin Yan,
  • Xuenan Zhang,
  • Fang Wang,
  • Takenobu Suzuki,
  • Yasutake Ohishi,
  • Tonglei Cheng

DOI
https://doi.org/10.3390/photonics7040089
Journal volume & issue
Vol. 7, no. 4
p. 89

Abstract

Read online

According to the beam propagation method, a fiber refractive index-sensitive multimode interference (MMI) structure fabricated by splicing a self-made silica glass rod between two single mode fibers (SMF–NCF (no core fiber)–SMF structure) is proposed for liquid level monitoring. Theoretical and experimental investigation was carried out meticulously using a 4.5 cm and a 9.5 cm long silica glass rod. It is proved that the simple and economical sensor with the shorter length has high sensitivity, satisfactory repeatability, and favorable stability. The sensitivity climbs with the increase in refractive index of the measured liquid, which is 204 pm/mm for pure water, 265.8 pm/mm for 10% glycerin solution, and 352.5 pm/mm for 25% glycerin solution. The proposed sensor can be standardized in certain application circumstances to achieve accurate liquid level monitoring.

Keywords