Effect of modified high-flow oxygen therapy on positive end-expiratory pressure and end-expiratory lung volume based on simulated lung platform

  • Kunming Cheng,
  • Wanqing Li,
  • Yanqiu Lu,
  • Haiyang Wu,
  • Jianxin Zhou

Journal volume & issue
Vol. 9, no. 8
p. e19119

Abstract

Read online

Objective: The aim of this study was to assess the effect of modified high-flow oxygen therapy on end-expiratory lung volume (EELV) and positive end-expiratory pressure (PEEP) in tracheotomized patients with normal pulmonary, acute hypoxic respiratory failure (AHRF) or chronic obstructive pulmonary disease (COPD). Methods: A ventilator and an artificial lung model were used to simulate the normal or strong inspiratory effort state of normal lung, AHRF and COPD patients. The traditional high-flow respiratory humidification therapy device connected with a standard interface (group A), and the modified therapy device added two types of resistance valves (group B, inner diameter 7.7 mm, length 24.0 mm; group C, inner diameter 7.7 mm, length 34.0 mm) to the exhalation end of the standard interface. The changes of end-expiratory lung volume (ΔEELV) and PEEP with the increase of flow rate (10 L/min, 20 L/min, 30 L/min, 40 L/min, 50 L/min, 60 L/min) in the three groups was recorded. Results: Under simulated conditions of normal lung, AHRF and COPD, as the flow rate increased by using the modified therapy device, the PEEP values in all groups showed an exponential increasing trend, and the ΔEELV also increased accordingly. In addition, under the same flow rate level, the PEEP values of the two modified high-flow oxygen therapies (Group B and Group C) were significantly higher than those of the standard high-flow oxygen therapy (Group A) (p < 0.05). In the normal lung model with normal or strong inspiratory effort, and in the AHRF or COPD model with strong inspiratory effort, when the flow rate was higher than 30 L/min, the PEEP levels of Group B were significantly lower than those of Group C (p < 0.05). In the AHRF model with normal inspiratory effort, when the flow rate was between 10 L/min and 60 L/min, the PEEP levels of Group B were significantly lower than those of Group C (p < 0.05). Moreover, in the COPD model with normal inspiratory effort, the PEEP levels of Group B were significantly lower than that of Group C only when the flow rate was 60 L/min (p < 0.05). Conclusion: The addition of different types of resistance valves to the high-flow exhalation end may be a feasible solution to improve the clinical efficacy of tracheotomized high-flow oxygen therapy.

Keywords