Case Studies in Thermal Engineering (Nov 2024)
Research on multi-energy coupled preheating system of city gate station based on Modelica simulation
Abstract
Natural gas depressurization at city gate stations can cause hydrate formation, necessitating preheating before pressure regulation. To reduce the high energy consumption of traditional city gate station preheating processes, this study introduces four novel multi-energy coupled systems: photovoltaic-air source heat pump (PV-ASHP), solar thermal-combined heat and power-ASHP (ST-CHP-ASHP), CHP-ASHP, and ASHP system, with a typical city gate station in Shanghai taken as the research case. Dynamic energy simulation systems were developed in Dymola software to evaluate the proposed systems from energy, environmental, and economic perspectives, conducting a comparison with conventional boiler preheating systems, including sensitivity analysis of energy prices on system economics. Results indicate PV-ASHP has the lowest annual total cost (ATC) and shortest discounted payback period, while ATC values for ST-CHP-ASHP, CHP-ASHP, and ASHP increase by 6.4 %, 9.6 %, and 12.6 %, respectively. ST-CHP-ASHP and PV-ASHP demonstrate advantages in primary energy rate and carbon emissions, with ST-CHP-ASHP performing slightly better than PV-ASHP. Currently, PV-ASHP demonstrates the highest development potential. If photovoltaic feed-in tariffs remain constant, and natural gas prices decrease by over 12.5 % or CHP feed-in tariffs increase by over 38.4 %, ST-CHP-ASHP becomes more economically viable. This research provides valuable insights for retrofitting China's existing city gate station preheating systems.