Journal of Hebei University of Science and Technology ()

Diagnosis of inverter switch open circuit faults based on neutral point voltage signal analysis

  • Liwei GUO,
  • Shenglong ZHOU,
  • Guoqing AN,
  • Xuejiao WANG

DOI
https://doi.org/10.7535/hbkd.2015yx01010
Journal volume & issue
Vol. 36, no. 1
pp. 45 – 51

Abstract

Read online

Using the current signal to diagnose inverter faults information is apt to be affected by the load, noise and other factors; besides, it requires long diagnosis period with special algorithms and the diagnosis result is easily to be incorrect with no-load or light-load. Focusing on this issue, the logical analysis method is proposed for correlation logical analysis of leg neutral-point voltage and pulse signal to realize the diagnosis of the open circuit faults of inverter switches. The logical expressions of output signals of inverter power tube open-circuit faults is put forward and interrelated hardware circuit design is also elaborated. Delaying the rising edge of inverter power tube's pulse signal can effectively avoid the diagnosis error caused by the power tube's switching on/off. The experiment results show that the method can effectively diagnose the open-circuit faults of single-phase single power tube inverter in real-time and the hardware circuit cost is low, which shows it is effective and feasible.

Keywords