Assessments of Facial Muscle Thickness by Ultrasound in Younger Adults: Absolute and Relative Reliability
Takashi Abe,
Robert W. Spitz,
Vickie Wong,
Ricardo B. Viana,
Yujiro Yamada,
Zachary W. Bell,
Raksha N. Chatakondi,
Jeremy P. Loenneke
Affiliations
Takashi Abe
Department of Health, Exercise Science, & Recreation Management, Kevser Ermin Applied Physiology Laboratory, The University of Mississippi, University, MS 38677, USA
Robert W. Spitz
Department of Health, Exercise Science, & Recreation Management, Kevser Ermin Applied Physiology Laboratory, The University of Mississippi, University, MS 38677, USA
Vickie Wong
Department of Health, Exercise Science, & Recreation Management, Kevser Ermin Applied Physiology Laboratory, The University of Mississippi, University, MS 38677, USA
Ricardo B. Viana
Department of Health, Exercise Science, & Recreation Management, Kevser Ermin Applied Physiology Laboratory, The University of Mississippi, University, MS 38677, USA
Yujiro Yamada
Department of Health, Exercise Science, & Recreation Management, Kevser Ermin Applied Physiology Laboratory, The University of Mississippi, University, MS 38677, USA
Zachary W. Bell
Department of Health, Exercise Science, & Recreation Management, Kevser Ermin Applied Physiology Laboratory, The University of Mississippi, University, MS 38677, USA
Raksha N. Chatakondi
Department of Health, Exercise Science, & Recreation Management, Kevser Ermin Applied Physiology Laboratory, The University of Mississippi, University, MS 38677, USA
Jeremy P. Loenneke
Department of Health, Exercise Science, & Recreation Management, Kevser Ermin Applied Physiology Laboratory, The University of Mississippi, University, MS 38677, USA
The absolute reliability (i.e., standard error of measurement and minimal difference) of a measurement is important to consider when assessing training effects. However, the absolute reliability for ultrasound measured facial muscle thickness had not been investigated. In order to examine the absolute and relative reliability of measuring facial muscles, 98 healthy, young, and middle-aged adults (18–40 years) had ultrasound measurements taken twice, separated by an average of three days. Six facial muscles were selected to determine the reliability of facial muscle thickness. The relative reliability (ICC3,1) ranged from 0.425 for the orbicularis oris (inferior) to 0.943 for the frontalis muscle. The absolute reliability (minimal difference) ranged from 0.25 mm for the orbicularis oculi to 1.82 mm for the masseter. The percentage minimal difference was 22%, 25%, 26%, 29%, 21%, and 10% for the frontalis, orbicularis oculi, orbicularis oris (superior), orbicularis oris (inferior), depressor anguli oris, and masseter, respectively. Our results indicated that the relative reliability was similar to that observed previously. The absolute reliability indicated that the measurement error associated with measuring muscle thickness of the face may be greater than that of the trunk/limb muscles. This may be related to the difficulty of accurately determining the borders of each muscle.