Water Sampling Module for Collecting and Concentrating <i>Legionella pneumophila</i> from Low-to-Medium Contaminated Environment
Khalid Moumanis,
Lilian Sirbu,
Walid Mohamed Hassen,
Eric Frost,
Lydston Rodrigues de Carvalho,
Pierre Hiernaux,
Jan Jerzy Dubowski
Affiliations
Khalid Moumanis
Laboratory for Quantum Semiconductors and Photon-Based BioNanotechnology, Interdisciplinary Institute for Technological Innovation (3IT), CNRS UMI-3463, Université de Sherbrooke, 3000 boul. de l’Université, Sherbrooke, QC J1K 0A5, Canada
Lilian Sirbu
Laboratory for Quantum Semiconductors and Photon-Based BioNanotechnology, Interdisciplinary Institute for Technological Innovation (3IT), CNRS UMI-3463, Université de Sherbrooke, 3000 boul. de l’Université, Sherbrooke, QC J1K 0A5, Canada
Walid Mohamed Hassen
Laboratory for Quantum Semiconductors and Photon-Based BioNanotechnology, Interdisciplinary Institute for Technological Innovation (3IT), CNRS UMI-3463, Université de Sherbrooke, 3000 boul. de l’Université, Sherbrooke, QC J1K 0A5, Canada
Eric Frost
Laboratory for Quantum Semiconductors and Photon-Based BioNanotechnology, Interdisciplinary Institute for Technological Innovation (3IT), CNRS UMI-3463, Université de Sherbrooke, 3000 boul. de l’Université, Sherbrooke, QC J1K 0A5, Canada
Lydston Rodrigues de Carvalho
Produits Chimiques Magnus Limitée, 1271, rue Ampère, Boucherville, QC J4B 5Z5, Canada
Pierre Hiernaux
Produits Chimiques Magnus Limitée, 1271, rue Ampère, Boucherville, QC J4B 5Z5, Canada
Jan Jerzy Dubowski
Laboratory for Quantum Semiconductors and Photon-Based BioNanotechnology, Interdisciplinary Institute for Technological Innovation (3IT), CNRS UMI-3463, Université de Sherbrooke, 3000 boul. de l’Université, Sherbrooke, QC J1K 0A5, Canada
The detection of water contamination with Legionella pneumophila is of critical importance to manufacturers of water processing equipment and public health entities dealing with water networks and distribution systems. Detection methods based on polymerase chain reaction or biosensor technologies require preconcentration steps to achieve attractive sensitivity levels. Preconcentration must also be included in protocols of automated collection of water samples by systems designed for quasi-continuous monitoring of remotely located water reservoirs for the presence of L. pneumophila. We designed and characterized a water sampling module for filtration and backwashing intended for analysis of low-to-medium contaminated water, typically with L. pneumophila bacteria not exceeding 50 colony-forming units per milliliter. The concentration factors of 10× and 21× were achieved with 0.22 and 0.45 µm filters, respectively, for samples of bacteria prepared in clean saline solutions. However, a 5× concentration factor was achieved with 0.45 µm filters for a heavily contaminated or turbid water typical of some industrial water samples.