Journal of Cardiovascular Magnetic Resonance (Mar 2023)

Developing a medical device-grade T2 phantom optimized for myocardial T2 mapping by cardiovascular magnetic resonance

  • Constantin-Cristian Topriceanu,
  • Massimiliano Fornasiero,
  • Han Seo,
  • Matthew Webber,
  • Kathryn E. Keenan,
  • Karl F. Stupic,
  • Rüdiger Bruehl,
  • Bernd Ittermann,
  • Kirsty Price,
  • Louise McGrath,
  • Wenjie Pang,
  • Alun D. Hughes,
  • Reza Nezafat,
  • Peter Kellman,
  • Iain Pierce,
  • James C. Moon,
  • Gabriella Captur

DOI
https://doi.org/10.1186/s12968-023-00926-z
Journal volume & issue
Vol. 25, no. 1
pp. 1 – 14

Abstract

Read online

Abstract Introduction A long T2 relaxation time can reflect oedema, and myocardial inflammation when combined with increased plasma troponin levels. Cardiovascular magnetic resonance (CMR) T2 mapping therefore has potential to provide a key diagnostic and prognostic biomarkers. However, T2 varies by scanner, software, and sequence, highlighting the need for standardization and for a quality assurance system for T2 mapping in CMR. Aim To fabricate and assess a phantom dedicated to the quality assurance of T2 mapping in CMR. Method A T2 mapping phantom was manufactured to contain 9 T1 and T2 (T1|T2) tubes to mimic clinically relevant native and post-contrast T2 in myocardium across the health to inflammation spectrum (i.e., 43–74 ms) and across both field strengths (1.5 and 3 T). We evaluated the phantom’s structural integrity, B 0 and B 1 uniformity using field maps, and temperature dependence. Baseline reference T1|T2 were measured using inversion recovery gradient echo and single-echo spin echo (SE) sequences respectively, both with long repetition times (10 s). Long-term reproducibility of T1|T2 was determined by repeated T1|T2 mapping of the phantom at baseline and at 12 months. Results The phantom embodies 9 internal agarose-containing T1|T2 tubes doped with nickel di-chloride (NiCl2) as the paramagnetic relaxation modifier to cover the clinically relevant spectrum of myocardial T2. The tubes are surrounded by an agarose-gel matrix which is doped with NiCl2 and packed with high-density polyethylene (HDPE) beads. All tubes at both field strengths, showed measurement errors up to ≤ 7.2 ms [< 14.7%] for estimated T2 by balanced steady-state free precession T2 mapping compared to reference SE T2 with the exception of the post-contrast tube of ultra-low T1 where the deviance was up to 16 ms [40.0%]. At 12 months, the phantom remained free of air bubbles, susceptibility, and off-resonance artifacts. The inclusion of HDPE beads effectively flattened the B 0 and B 1 magnetic fields in the imaged slice. Independent temperature dependency experiments over the 13–38 °C range confirmed the greater stability of shorter vs longer T1|T2 tubes. Excellent long-term (12-month) reproducibility of measured T1|T2 was demonstrated across both field strengths (all coefficients of variation < 1.38%). Conclusion The T2 mapping phantom demonstrates excellent structural integrity, B 0 and B 1 uniformity, and reproducibility of its internal tube T1|T2 out to 1 year. This device may now be mass-produced to support the quality assurance of T2 mapping in CMR.

Keywords