Journal of Biomedical Physics and Engineering (Aug 2019)

Signal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer

  • Rezaeian A.,
  • Tahmasebi Birgani M. J.,
  • Chegeni N.,
  • Sarkarian M.,
  • Hanafi M. Gh.,
  • Akbarizadeh Gh.

Journal volume & issue
Vol. 9, no. 4
pp. 453 – 458

Abstract

Read online

Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characterization. Objective: To assess based on histopathological findings of transrectal ultrasound (TRUS)-guided prostate biopsy as a reference, an increase in signal intensity of prostatic lesions in comparison with normal background tissue on high b-value diffusion-weighted images could be a sign of malignancy. Material and Methods: Fifty-three consecutive patients retrospectively included in the study. All patients underwent routine TRUS-guided prostate biopsies involving 12 cores after the magnetic resonance imaging (MRI) examinations. In seventeen patients (n =35 lesions), the prostate cancer was histologically confirmed by TRUS-guided prostate biopsy. The biopsy results of other patients were negative. Signal intensities on the high b-value (1600 s/mm2 ) images of the peripheral zone, the central gland, and the defined lesions were evaluated using region of interestbased measurements. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for prostate cancer detection using signal intensity of high b value diffusion-weighted images were calculated. Results: In the patients with confirmed prostate cancer, fourteen had visually increased SI on the high b-value images. The SI of lesions for these patients was higher than the SI of peripheral zone (22±18%) or central gland (31±20%). In patients with a negative biopsy, eight had visually increased SI on the high b-value images. The SI of lesions for these patients was 23±21% and 35±18% higher than the SI in the peripheral zone and the central gland, respectively. The sensitivity, specificity, PPV, and NPV for prostate cancer using SI of high b value DWI were 71, 87, 62, and 87 %, respectively. Conclusion: Visually increased SI on the high b-value images can be an indication of malignancy, although some benign lesions also show this increase in signal intensity. Citation: Rezaeian A, Tahmasebi Birgani M. J, Chegeni N, Sarkarian M, Hanafi M. Gh, Akbarizadeh Gh. Signal Intensity of High B-value Dif- fusion-weighted Imaging for the Detection of Prostate Cancer. J Biomed Phys Eng. 2019;9(4):453-458. https://doi.org/10.31661/jbpe.v0i0.811.

Keywords