Journal of Optometry (Jan 2015)

Overnight corneal swelling with high and low powered silicone hydrogel lenses

  • Amir M. Moezzi,
  • Desmond Fonn,
  • Jalaiah Varikooty,
  • Trefford L. Simpson

DOI
https://doi.org/10.1016/j.optom.2014.03.002
Journal volume & issue
Vol. 8, no. 1
pp. 19 – 26

Abstract

Read online

Purpose: To compare central corneal swelling after eight hours of sleep in eyes wearing four different silicone hydrogel lenses with three different powers. Methods: Twenty-nine neophyte subjects wore lotrafilcon A (Dk, 140), balafilcon A (Dk, 91), galyfilcon A (Dk, 60) and senofilcon A (Dk, 103) lenses in powers −3.00, −10.00 and +6.00 D on separate nights, in random order, and on one eye only. The contra-lateral eye (no lens) served as the control. Central corneal thickness was measured using a digital optical pachometer before lens insertion and immediately after lens removal on waking. Results: For the +6.00 D and −10.00 D, lotrafilcon A induced the least swelling and galyfilcon A the most. The +6.00 D power, averaged across lens materials, induced significantly greater central swelling than the −10.00 and −3.00 D (Re-ANOVA, p < 0.001), (7.7 ± 2.9% vs. 6.8 ± 2.8% and 6.5 ± 2.5% respectively) but there was no difference between −10.00 and −3.00 D. Averaged for power, lotrafilcon A induced the least (6.2 ± 2.8%) and galyfilcon A the most (7.6 ± 3.0%) swelling at the center (Re-ANOVA, p < 0.001). Central corneal swelling with +6.00 D was significantly greater than −10.00 D lens power despite similar levels of average lens transmissibility of these two lens powers. Conclusions: The differences in corneal swelling of the lens wearing eyes are consistent with the differences in oxygen transmission of the silicone hydrogel lenses. In silicone hydrogel lenses central corneal swelling is mainly driven by central lens oxygen transmissibility.

Keywords