A Modified Endoscopic Carpal Tunnel Release Surgery
Jianyun Yang,
Jing Xu,
Yinglu Zhao,
Xiaotian Jia
Affiliations
Jianyun Yang
Department of Hand Surgery, Huashan Hospital, Fudan University; Key Laboratory of Hand Reconstruction, Ministry of Health; Shanghai Key Laboratory of Peripheral Nerve and Microsurgery
Jing Xu
Department of Hand Surgery, Huashan Hospital, Fudan University; Key Laboratory of Hand Reconstruction, Ministry of Health; Shanghai Key Laboratory of Peripheral Nerve and Microsurgery
Yinglu Zhao
Department of Hand Surgery, Huashan Hospital, Fudan University; Key Laboratory of Hand Reconstruction, Ministry of Health; Shanghai Key Laboratory of Peripheral Nerve and Microsurgery
Xiaotian Jia
Department of Hand Surgery, Huashan Hospital, Fudan University; Key Laboratory of Hand Reconstruction, Ministry of Health; Shanghai Key Laboratory of Peripheral Nerve and Microsurgery; Corresponding author: Xiaotian Jia, Telephone number: +86-13761854981, Fax: None, Postal address: Department of Hand Surgery, Huashan Hospital, 12 Wulumuqi Zhong Road, Shanghai, China. 200040.
Summary: In this study, a modified version of the endoscopic carpal tunnel release surgery was introduced, which is safe and easy to handle. Moreover, the requirement for surgical instruments is low. Six patients with carpal tunnel syndrome underwent the modified procedure. No neurovascular injuries occurred in these patients. According to the one-year follow-up data, all the patients were satisfied with the outcomes. The modified endoscopic carpal tunnel release technique has been proven to be safe with satisfactory outcomes in six patients in this study.