American Journal of Ophthalmology Case Reports (Mar 2023)
Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy
Abstract
Purpose: To report a series of 8 phakic eyes of 8 patients with open angle glaucoma with uncontrolled intraocular pressure on maximum tolerable medical therapy receiving Hydrus Microstent implants combined with concomitant OMNI Surgical System ab interno canaloplasty. Observations: 8 phakic eyes underwent Hydrus Microstent implantation with OMNI Surgical System ab interno canaloplasty. 2 patients underwent concurrent Kahook Dual Blade goniotomy and 1 patient underwent a concurrent micropulse transscleral cyclophotocoagulation. 6 out of 8 eyes achieved successful intraocular pressure reduction. Only 1 achieved success without the need for additional medical therapy. 1 required Neodymium-doped yttrium aluminum garnet laser to clear iris obstruction of the Hydrus inlet and 1 required selective laser trabeculoplasty for additional intraocular pressure lowering. 2 out of 8 eyes required subsequent incisional glaucoma surgery for unacceptable intraocular pressure levels despite maximum tolerable medical therapy. Conclusions and Importance: The Hydrus Microstent combined with OMNI Surgical System ab interno canaloplasty can safely and successfully reduce intraocular pressure in phakic patients with open-angle glaucoma with uncontrolled intraocular pressure on maximum tolerable medical therapy with a low complication rate and rapid visual recovery.