Guoji Yanke Zazhi (Jun 2017)

Anterior segment biometry of eyes with different axial lengths

  • Wei Fang,
  • Jian Zhang,
  • Hui-Qing Yang,
  • Li-Ping Zhao

DOI
https://doi.org/10.3980/j.issn.1672-5123.2017.6.11
Journal volume & issue
Vol. 17, no. 6
pp. 1055 – 1059

Abstract

Read online

AIM: To research the correlation factor of the anterior segment values of eyes with different axial lengths. METHODS: In this study, 697 cases 697 eyes were included. According to axial length we divided all the cases into short axial length group, normal axial length group, mild long axial length group, moderate long axial length group and severe long axial length group. The relevant indicators of the anterior segment values of patients in the five groups was comparatively analyzed.RESULTS: In the short axial length group, the anterior chamber volume(ACV)showed a significantly negative correlation with age; anterior chamber depth(ACD)showed a significantly negative correlation with age. In the normal axial length group, the ACV showed a significantly negative correlation with age and a significantly positive correlation with axial length(AXL); the anterior chamber angle(ACA)showed a significantly negative correlation with age and a significantly positive correlation with AXL, and a significantly positive correlation with corneal curvature; the ACD showed a significantly negative correlation with age and a significantly positive correlation with AXL. In the mild long axial length group, the ACV showed a significantly negative correlation with age and a significantly positive correlation with AXL, and a significantly negative correlation with corneal curvature; the ACA showed a significantly negative correlation with age and a significantly positive correlation with AXL, and a significantly positive correlation with corneal curvature; the ACD showed a significantly negative correlation with age and a significantly positive correlation with AXL. In the moderate long axial length group, the ACV showed a significantly negative correlation with age; the ACA showed a significantly positive correlation with AXL; the ACD showed a significantly positive correlation with AXL. In the severe long axial length group, the ACV showed a significantly negative correlation with age. There were no significant differences on ACV, ACA and ACD among mild long axial length group, moderate long axial length group and severe long axial length group(P>0.05), while the difference between other groups was significant(PCONCLUSION: There has a correlation between the anterior chamber values(ACV, ACA, ACD)age and AXL for eyes which AXL were 22-27mm, while the correlation would disappear as the AXL became shorter or longer. There was a significant growth trend of anterior chamber values for eyes with AXL <27mm.

Keywords