Prova broncodilatadora na espirometria: efeito do uso de espaçador de grande volume com tratamento antiestático na resposta ao broncodilatador Spirometry with bronchodilator test: effect that the use of large-volume spacers with antistatic treatment has on test response

  • Flávia de Barros Araújo,
  • Ricardo de Amorim Corrêa,
  • Luis Fernando Ferreira Pereira,
  • Carla Discacciati Silveira,
  • Eliane Viana Mancuso,
  • Nilton Alves de Rezende

DOI
https://doi.org/10.1590/S1806-37132011000600008
Journal volume & issue
Vol. 37, no. 6
pp. 752 – 758

Abstract

Read online

OBJETIVO: Avaliar se o uso de salbutamol inalatório através de inalador dosimetrado acoplado a espaçadores de grande volume com tratamento antiestático na espirometria com prova broncodilatadora modifica os resultados do teste quando comparado à técnica usual (sem espaçador). MÉTODOS: Estudo prospectivo envolvendo 24 pacientes, com idades entre 18 e 45 anos e suspeita clínica de asma, atendidos no Ambulatório de Pneumologia do Hospital das Clínicas da Universidade Federal de Minas Gerais, em Belo Horizonte (MG). Os pacientes foram submetidos a duas espirometrias com prova broncodilatadora realizadas com e sem o uso de espaçador de grande volume. RESULTADOS: Não houve diferença significativa na variação do VEF1 antes e após o uso de broncodilatador entre as duas técnicas (ΔVEF1 média = 0,01 L; IC95%: -0,05 a 0,06; p = 0,824). Não houve diferença estatisticamente significativa entre as duas técnicas em relação ao resultado qualitativo da prova broncodilatadora (p = 1,00). Houve concordância dos resultados da prova broncodilatadora entre as técnicas (coeficiente kappa = 0,909; p OBJECTIVE: To evaluate whether the use of inhaled albuterol via a metered-dose inhaler with a large-volume spacer with antistatic treatment modifies the bronchodilator test results when compared with the usual technique (no spacer). METHODS: A prospective study involving 24 patients, 18-45 years of age, clinically suspected of having asthma, and under treatment at the Outpatient Pulmonary Clinic of the Federal University of Minas Gerais Hospital das Clínicas, located in the city of Belo Horizonte, Brazil. All of the patients underwent two bronchodilator tests: one with and one without the use of a large-volume spacer. RESULTS: There was no significant difference in the variation of FEV1 prior to and after bronchodilator use between the two techniques (mean ΔFEV1 = 0.01 L; 95% CI: -0.05 to 0.06; p = 0.824). No statistically significant difference was found between the two techniques regarding the qualitative results on the bronchodilator test (p = 1.00). There was concordance between the techniques in terms of the bronchodilator test results (kappa coefficient = 0.909; p < 0.005). CONCLUSIONS: According to the results of this study, the use of large-volume spacers does not significantly modify bronchodilator test results.

Keywords