Journal of Personalized Medicine (Mar 2022)

Normal Lung Tissue CT Density Changes after Volumetric-Arc Radiotherapy (VMAT) for Lung Cancer

  • Marek Konkol,
  • Maciej Bryl,
  • Marek Fechner,
  • Krzysztof Matuszewski,
  • Paweł Śniatała,
  • Piotr Milecki

DOI
https://doi.org/10.3390/jpm12030485
Journal volume & issue
Vol. 12, no. 3
p. 485

Abstract

Read online

Radiation-induced lung injury remains a significant toxicity in thoracic radiotherapy. Because a precise diagnosis is difficult and commonly used assessment scales are unclear and subjective, there is a need to establish quantitative and sensitive grading methods. The lung tissue density change expressed in Hounsfield units (HUs) derived from CT scans seems a useful numeric surrogate. The study aimed to confirm a dose-response effect on HU value changes (ΔHU), their evolution in time, and the impact of selected clinical and demographic factors. We used dedicated, self-developed software to register and analyze 120 pairs of initial and follow-up CT scans of 47 lung cancer patients treated with dynamic arc radiotherapy. The differences in HU values between CT scans were calculated within discretized dose-bins limited by isodose lines. We have proved the dose-effect relationship, which is well described with a sigmoid model. We found the time evolution of HU changes to suit a typical clinical presentation of radiation-induced toxicity. Some clinical factors were found to correlate with ΔHU degree: planning target volume (PTV), V35 in the lung, patient’s age and a history of arterial hypertension, and initial lung ventilation intensity. Lung density change assessment turned out to be a sensitive and valuable method of grading post-RT lung toxicity.