In vivo skin anisotropy dataset from annular suction test
Aflah Elouneg,
Audrey Bertin,
Quentin Lucot,
Vincent Tissot,
Emmanuelle Jacquet,
Jérôme Chambert,
Arnaud Lejeune
Affiliations
Aflah Elouneg
Applied Mechanics Department, FEMTO-ST Institute, University Bourgogne Franche-Comté, CNRS (UMR 6174), 24 Rue de L’Épitaphe, Besançon 25000, France
Audrey Bertin
Applied Mechanics Department, FEMTO-ST Institute, University Bourgogne Franche-Comté, CNRS (UMR 6174), 24 Rue de L’Épitaphe, Besançon 25000, France; Biomedical Engineering School at University of Franche-Comté, University Bourgogne Franche-Comté, 23 rue Alain Savary, Besançon 25000, France
Quentin Lucot
Applied Mechanics Department, FEMTO-ST Institute, University Bourgogne Franche-Comté, CNRS (UMR 6174), 24 Rue de L’Épitaphe, Besançon 25000, France
Vincent Tissot
Applied Mechanics Department, FEMTO-ST Institute, University Bourgogne Franche-Comté, CNRS (UMR 6174), 24 Rue de L’Épitaphe, Besançon 25000, France
Emmanuelle Jacquet
Applied Mechanics Department, FEMTO-ST Institute, University Bourgogne Franche-Comté, CNRS (UMR 6174), 24 Rue de L’Épitaphe, Besançon 25000, France; Biomedical Engineering School at University of Franche-Comté, University Bourgogne Franche-Comté, 23 rue Alain Savary, Besançon 25000, France; Corresponding author at: Applied Mechanics Department, FEMTO-ST Institute, University Bourgogne Franche-Comté, CNRS (UMR 6174), 24 Rue de L’Épitaphe, Besançon 25000, France.
Jérôme Chambert
Applied Mechanics Department, FEMTO-ST Institute, University Bourgogne Franche-Comté, CNRS (UMR 6174), 24 Rue de L’Épitaphe, Besançon 25000, France
Arnaud Lejeune
Applied Mechanics Department, FEMTO-ST Institute, University Bourgogne Franche-Comté, CNRS (UMR 6174), 24 Rue de L’Épitaphe, Besançon 25000, France
To characterize the anisotropic and viscoelastic behaviors of the skin, we conducted an experimental campaign of in-vivo suction tests using the CutiScan®CS100 device from Courage and Khazaka electronics. In this data paper, we present the raw acquired data of the tests and their respective treated data. The tests were performed 30 times on the anterior forearm of a 28-year-old Caucasian male at different pressure set-points, ranging from 100 to 500 mbar with an increment of 20 mbar, at ambient temperature in a windowless room. The primary dataset consists of videos recorded by a probe camera associated with the CutiScan® device during the tests. After data treatment with DIC (Digital Image Correlation) technique and based on a homemade Python program, we have obtained secondary data tables and 2D displacement for all mapped grid nodes.